247 research outputs found

    Development of a telescope for medium-energy gamma-ray astronomy

    Get PDF
    The Advanced Energetic Pair Telescope (AdEPT) is being developed at GSFC as a future NASA MIDEX mission to explore the medium-energy (5–200 MeV) gamma-ray range. The enabling technology for AdEPT is the Three- Dimensional Track Imager (3-DTI), a gaseous time projection chamber. The high spatial resolution 3-D electron tracking of 3-DTI enables AdEPT to achieve high angular resolution gamma-ray imaging via pair production and triplet production (pair production on electrons) in the medium-energy range. The low density and high spatial resolution of 3-DTI allows the electron positron track directions to be measured before they are dominated by Coulomb scattering. Further, the significant reduction of Coulomb scattering allows AdEPT to be the first medium-energy gamma-ray telescope to have high gamma-ray polarization sensitivity. We review the science goals that can be addressed with a medium-energy pair telescope, how these goals drive the telescope design, and the realization of this design with AdEPT. The AdEPT telescope for a future MIDEX mission is envisioned as a 8 m3 active volume filled with argon at 2 atm. The design and performance of the 3-DTI detectors for the AdEPT telescope are described as well as the outstanding instrument challenges that need to be met for the AdEPT mission

    Negative Ion Drift Velocity and Longitudinal Diffusion in Mixtures of Carbon Disulfide and Methane

    Get PDF
    Negative ion drift velocity and longitudinal diffusion has been measured for gas mixtures of carbon disulfide (CS2) and methane (CH4)' Measurements were made as a function of total pressure, CS2 partial pressure and electric field. Constant mobility and thermal-limit longitudinal diffusion is observed for all gas mixtures tested. Gas gain for some of the mixtures is also included

    Performance of the Ultra-High Rate Germanium (UHRGe) System

    Full text link
    Performance of the Ultra-High Rate Germanium (UHRGe) System client repor

    A very brief description of LOFAR - the Low Frequency Array

    Get PDF
    LOFAR (Low Frequency Array) is an innovative radio telescope optimized for the frequency range 30-240 MHz. The telescope is realized as a phased aperture array without any moving parts. Digital beam forming allows the telescope to point to any part of the sky within a second. Transient buffering makes retrospective imaging of explosive short-term events possible. The scientific focus of LOFAR will initially be on four key science projects (KSPs): 1) detection of the formation of the very first stars and galaxies in the universe during the so-called epoch of reionization by measuring the power spectrum of the neutral hydrogen 21-cm line (Shaver et al. 1999) on the ~5' scale; 2) low-frequency surveys of the sky with of order 10810^8 expected new sources; 3) all-sky monitoring and detection of transient radio sources such as gamma-ray bursts, x-ray binaries, and exo-planets (Farrell et al. 2004); and 4) radio detection of ultra-high energy cosmic rays and neutrinos (Falcke & Gorham 2003) allowing for the first time access to particles beyond 10^21 eV (Scholten et al. 2006). Apart from the KSPs open access for smaller projects is also planned. Here we give a brief description of the telescope.Comment: 2 pages, IAU GA 2006, Highlights of Astronomy, Volume 14, K.A. van der Hucht, e

    A pair production telescope for medium-energy gamma-ray polarimetry

    Get PDF
    We describe the science motivation and development of a pair production telescope for medium-energy (∼5–200 MeV) gamma-ray polarimetry. Our instrument concept, the Advanced Energetic Pair Telescope (AdEPT), takes advantage of the Three-Dimensional Track Imager, a low-density gaseous time projection chamber, to achieve angular resolution within a factor of two of the pair production kinematics limit (∼0.6° at 70 MeV), continuum sensitivity comparable with the Fermi-LAT front detector (<3 × 10−6 MeV cm−2 s−1 at 70 MeV), and minimum detectable polarization less than 10% for a 10 mCrab source in 106 s.submittedVersionFil: Hunter, Stanley D. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Fil: Bloser, Peter F. University of New Hampshire. Institute for the Study of Earth, Oceans, and Space. Space Science Center; Estados Unidos de América.Fil: Depaola, Gerardo Osvaldo. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física; Argentina.Fil: Dion, Michael P. Department of Energy. Office of Science. Pacific Northwest National Laboratory; Estados Unidos de América.Fil: DeNolfo, Georgia A. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Fil: Hanu, Andrei. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Fil: Iparraguirre, Lorenzo Marcos. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía y Física; Argentina.Fil: Legere, Jason. University of New Hampshire. Institute for the Study of Earth, Oceans, and Space. Space Science Center; Estados Unidos de América.Fil: Longo, Francesco. Università Degli Studi de Trieste. Dipartimento di fisica; Italia.Fil: McConnell, Mark L. University of New Hampshire. Institute for the Study of Earth, Oceans, and Space. Space Science Center; Estados Unidos de América.Fil: Nowicki, Suzanne F. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Fil: Nowicki, Suzanne F. University of Maryland, Baltimore County. Department of Physics; Estados Unidos de América.Fil: Ryan, James M. University of New Hampshire. Institute for the Study of Earth, Oceans, and Space. Space Science Center; Estados Unidos de América.Fil: Son, Seunghee. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Fil: Son, Seunghee. University of Maryland, Baltimore County. Department of Physics; Estados Unidos de América.Fil: Stecker, Floyd W. National Aeronautics and Space Administration. Goddard Space Flight Center; Estados Unidos de América.Física de Partículas y Campo

    De novo mutations in SMCHD1 cause Bosma arhinia microphthalmia syndrome and abrogate nasal development

    Get PDF
    Bosma arhinia microphthalmia syndrome (BAMS) is an extremely rare and striking condition characterized by complete absence of the nose with or without ocular defects. We report here that missense mutations in the epigenetic regulator SMCHD1 mapping to the extended ATPase domain of the encoded protein cause BAMS in all 14 cases studied. All mutations were de novo where parental DNA was available. Biochemical tests and in vivo assays in Xenopus laevis embryos suggest that these mutations may behave as gain-of-function alleles. This finding is in contrast to the loss-of-function mutations in SMCHD1 that have been associated with facioscapulohumeral muscular dystrophy (FSHD) type 2. Our results establish SMCHD1 as a key player in nasal development and provide biochemical insight into its enzymatic function that may be exploited for development of therapeutics for FSHD

    Impact of Chromatin Structures on DNA Processing for Genomic Analyses

    Get PDF
    Chromatin has an impact on recombination, repair, replication, and evolution of DNA. Here we report that chromatin structure also affects laboratory DNA manipulation in ways that distort the results of chromatin immunoprecipitation (ChIP) experiments. We initially discovered this effect at the Saccharomyces cerevisiae HMR locus, where we found that silenced chromatin was refractory to shearing, relative to euchromatin. Using input samples from ChIP-Seq studies, we detected a similar bias throughout the heterochromatic portions of the yeast genome. We also observed significant chromatin-related effects at telomeres, protein binding sites, and genes, reflected in the variation of input-Seq coverage. Experimental tests of candidate regions showed that chromatin influenced shearing at some loci, and that chromatin could also lead to enriched or depleted DNA levels in prepared samples, independently of shearing effects. Our results suggested that assays relying on immunoprecipitation of chromatin will be biased by intrinsic differences between regions packaged into different chromatin structures - biases which have been largely ignored to date. These results established the pervasiveness of this bias genome-wide, and suggested that this bias can be used to detect differences in chromatin structures across the genome

    The ocean sampling day consortium

    Get PDF
    Ocean Sampling Day was initiated by the EU-funded Micro B3 (Marine Microbial Biodiversity, Bioinformatics, Biotechnology) project to obtain a snapshot of the marine microbial biodiversity and function of the world’s oceans. It is a simultaneous global mega-sequencing campaign aiming to generate the largest standardized microbial data set in a single day. This will be achievable only through the coordinated efforts of an Ocean Sampling Day Consortium, supportive partnerships and networks between sites. This commentary outlines the establishment, function and aims of the Consortium and describes our vision for a sustainable study of marine microbial communities and their embedded functional traits
    • …
    corecore